APAR status
Closed as Permanent restriction.
Error description
During RPC transmission of pure situation data from the agent to the TEMS, the last row of data gets truncated and is not sent. The following error is logged in the RAS1 trace file (57AAB643.19C1-D88:kraaamss.cpp,413,"groupDataRowsToBuffer") *A-INFO: KNT.NTEVTLOG.yqsun_test_event saved situation data rows exceed RPC transport limit, truncated!
Local fix
Problem summary
The maximum size of the buffer used to upload row data from Situations is 4096 bytes. If the Situation data retrieve is equal to or exceeds this byte count, then the last row(s) of data are truncated and the message situation data rows exceed RPC transport limit, truncated! can be found in the Agent log and missing from the Warehouse Database.
Problem conclusion
Revise the processing involved in buffer management such that the last row that fits into the buffer is uploaded.
Temporary fix
Provisional Fix IV40015 and IJ07905 resolve this issue. These APAR fixes are available upon receipt of a Provisional Fix request.
Comments
APAR Information
APAR number
IV90054
Reported component name
TEMA
Reported component ID
5724C04TE
Reported release
630
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-17
Closed date
2018-07-26
Last modified date
2018-07-26