IBM Support

IV90054: PURE EVENTS GET TRUNCATED DURING RPC TRANSMISSION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • During RPC transmission of pure situation data from the agent
    to the TEMS, the last row of data gets truncated and is not
    sent.
    The following error is logged in the RAS1 trace file
    (57AAB643.19C1-D88:kraaamss.cpp,413,"groupDataRowsToBuffer")
    *A-INFO: KNT.NTEVTLOG.yqsun_test_event saved situation data
    rows exceed RPC transport limit, truncated!
    

Local fix

Problem summary

  • The maximum size of the buffer used to upload row data from
    Situations is 4096 bytes.  If the Situation data retrieve
    is equal to or exceeds this byte count, then the last row(s) of
    data are truncated and the message
    
    situation data rows exceed RPC transport limit, truncated!
    
    can be found in the Agent log and missing from the Warehouse
    Database.
    

Problem conclusion

  • Revise the processing involved in buffer management such that
    the last row that fits into the buffer is uploaded.
    

Temporary fix

  • Provisional Fix IV40015 and IJ07905 resolve this issue. These
    APAR fixes are available upon receipt of a Provisional Fix
    request.
    

Comments

APAR Information

  • APAR number

    IV90054

  • Reported component name

    TEMA

  • Reported component ID

    5724C04TE

  • Reported release

    630

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-10-17

  • Closed date

    2018-07-26

  • Last modified date

    2018-07-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
08 March 2023