IBM Support

DataStage Job intermittently aborts with error "Message: Error setting up internal communications (fifo//./pipe/ETL_DS_SC197-ABC_generator)"

Troubleshooting


Problem

DataStage Job intermittently aborts with error "Message: Error setting up internal communications (fifo//./pipe/ETL_DS_SC197-ABC_generator)"

Symptom

Job intermittently aborts

Cause

Possible causes:

  • Lack of resource
  • Virus scan running for InformationServer, Project, $TMPDIR and scratch directories

Resolving The Problem

The following actions were taken to resolve the issue:

  1. Install IS 8.1 Fix Pack 1, which includes bundle_resourcemanagement_server_windows_81
  2. Configured virus scans to exclude the following Information Server directories
    • $TMPDIR, Temporary directories, e.g. /tmp on Unix/Linux and %TEMP% on Windows
    • Scratch directories

[{"Product":{"code":"SSZJPZ","label":"IBM InfoSphere Information Server"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
16 June 2018

UID

swg21445893