IBM Support

IC77793: AGENTCONNECTIONTIMEOUT PARAMETER TREATED AS MILLISECONDS VS SECONDS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Increasing the AgentConnectionTimeOut value in the server.config
    file as recommended in TPC Infocenter in order to prevent
    timeouts results in faster timeouts.
    This is because current code treats the value as milliseconds
    instead of seconds.
    The default setting for this parameter is 60000, if not
    specified in the server.config file.
    
    
    RECREATE STEPS:
    Follow recommended actions in TPC Infocenter.
    http://publib.boulder.ibm.com/infocenter/tivihelp/v4r1/index.jsp
    ?topic=%2Fcom.ibm.tpc_V421.doc%2Ffqz0_r_tbs_install_agents_sra1.
    html
    Action
    Increase the AgentConnectionTimeOut value in the server.config
    file. Change the value from 60 to 120 or 180. The server.config
    file is in the following directory:
    
    C:\Program Files\IBM\TPC\data\config (for Windows)
    /opt/IBM/TPC/data/config (for UNIX or Linux)
    
    Stop and restart the Data server.
    

Local fix

  • Multiply the recommended values by 1000.
    Change the value from 60000 to 120000 or 180000
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: TPC 4.2.x users adjusting the                *
    *                 AgentConnectionTimeOut value for the         *
    *                 Storage Resource Agents                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: See ERROR DESCRIPTION                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When the AgentConnectionTimeOut parameter is specified in
    server.config, the values are treated as milliseconds.
    The values specified in the help page (60 to 120 or 180) are
    not converted to milliseconds before use and results in SRA
    deployments timing out quickly.
    

Problem conclusion

  • A fix has been made so that the values read from server.config
    are converted to milliseconds.  The fix for this APAR is
    targeted for the following maintenance packages:
    
    | fix pack | 4.1.1-TIV-TPC-FP0007 - target to be determined
    | fix pack | 4.2.1-TIV-TPC-FP0004 - target August 2011
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future fix packs do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC77793

  • Reported component name

    TPC FOR DATA

  • Reported component ID

    5608TC300

  • Reported release

    41A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-07-29

  • Closed date

    2011-08-19

  • Last modified date

    2011-08-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC FOR DATA

  • Fixed component ID

    5608TC300

Applicable component levels

  • R41A PSY

       UP

  • R41H PSY

       UP

  • R41L PSY

       UP

  • R41S PSY

       UP

  • R41W PSY

       UP

  • R42A PSY

       UP

  • R42H PSY

       UP

  • R42L PSY

       UP

  • R42S PSY

       UP

  • R42W PSY

       UP