Error description
ABENDS/INVALID REGISTERS USING EZASMI WITH 3.2 TRANSFORM.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Any user of macro API ASSEMBLED with TCP/IP * * V3R1 and running on TCP/IP V3.2 base, where * * different modules issue EZASMI macros using * * the same TIE. * **************************************************************** * PROBLEM DESCRIPTION: An ABEND can occur upon return from * * EZASMI macro call due to corrupted * * registers. * **************************************************************** * RECOMMENDATION: none. * **************************************************************** When EZASOK03 is called by a second module using the same TIE, It does not build a new Save Area linkage. Therefore, when it returns from the macro, it restores the users registers to those last saved in the save area of the first calling module.
Problem conclusion
Module EZASOK03 was modified to create the correct SAVE AREA linkage on all invocations. Additional Symptoms: ABEND0c4, Abend0c1, DV12252 MV12252. ABENDA78-10
Temporary fix
Comments
APAR Information
APAR number
PN88249
Reported component name
TCP/IP V3 MVS
Reported component ID
5655HAL00
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1996-08-26
Closed date
1996-08-26
Last modified date
1998-08-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UN94504
Modules/Macros
EZASOK03
Fix information
Fixed component name
TCP/IP V3 MVS
Fixed component ID
5655HAL00
Applicable component levels
R320 PSY UN94504
UP96/09/02 P F608
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
16 August 1998