In Connect:Direct OS/400, after STRCD, the CDPMGR job fails with MCH2602 and CEE9901 (7.0.12298055.2898329)

Technote (troubleshooting)


Problem(Abstract)

In Connect:Direct OS/400, after STRCD, the CDPMGR job fails with MCH2602 and CEE9901 (7.0.12298055.2898329)

Symptom

After STRCD, the CDPMGR job fails with MCH2602 and CEE9901.
CEE9901
Error: Application error. MCH2602 unmonitored by QC2UTIL1.
MCH2602
Error: Lock request not given.


Cause

The Asset Protection Key file was not found when the INITPARM file was checked.

Resolving the problem

In the Connect:Direct parameters, change the Asset protection key file parameter to the correct library/file(member).

Historical Number

PRI4448

Product Alias/Synonym

Fact


Connect:Direct OS/400, All Releases
7.0.12298055.2898329