IGD104I DATA.SET.NAME NOT DEFINED BECAUSE DUPLICATE NAME EXISTS IN CATALOG (SCI85971)

Technote (troubleshooting)


Problem(Abstract)

IGD104I DATA.SET.NAME NOT DEFINED BECAUSE DUPLICATE NAME EXISTS IN CATALOG (SCI85971)

Symptom

IGD104I RDXJAW.STOUT0.SYSIN.T000672 RETAINED, DDNAME=SYS02346 NOT DEFINED BECAUSE DUPLICATE NAME EXISTS IN CATALOG

Cause

The ICO? data set? name was not unique for each file

Resolving the problem

Change process to specify the Connect:Enterprise batch number in the? data set? name.


&BATCHNO=%BATCHNO


SYMBOL?  &SEQ1=\T\ || &BATCHNO

Historical Number

PRI29588

Product Alias/Synonym

Change


Multiple files added to? Connect:Enterprise via FTP invoking multiple ICO's.

Fact


Connect:Enterprise OS/390
Inter Connect Option
ICO
Process
contains : &SEQ=%NUM1

Connect:Direct OS/390
SCI85971

Rate this page:

(0 users)Average rating

Document information


More support for:

Sterling Connect:Enterprise

Software version:

All

Operating system(s):

All

Reference #:

1529748

Modified date:

2007-08-27

Translate my page

Machine Translation

Content navigation