A fix is available
APAR status
Closed as program error.
Error description
The GUID is used as unique Identification for an agent, thus when a TPC Server gets data from an Data Agent/Storage Resource Agent we use unique GUID to identify the agent and save its respective data. This means that if there are multiple agents with same GUID they just keep overwriting the data from each other. This problem gets manifested by fact that deployment of machines and/or VMs using image replication is very common practice. Hence we can expect quite a few customer to run in to issue. We publish a way force regeneration of GUID for such situations, which need to be followed before the master imaged is built. i.e. TPC Hints and Tips Guide v.4.1.x http://www-01.ibm.com/support/docview.wss?uid=swg27008254&aid=1 Refer to: Section 5.2 'Creating a master image to clone TPC Agent machines' Which explains how to correctly create a master image used for cloning, thus, eliminating the duplicate TIVGUID issue. However, this procedure is often not used because the personnel building the OS images are not supporting TPC. To protect TPC from overwriting agent information we need a better protection in place. We need to modify our agent registration process as follows: 1. At agent (SRA/Data agent) registration time by default TPC server must not allow an agent to register if the an(another or same we can not distinguish) agent already registered using same GUID. ( Note that this check should be done at new registration time only. Probe and scan etc should continue working with current logic of overwriting info using the GUID as unique identifier. ) This would it turn fail the SRA installation on the machine which try to register with that GUID. 2. As we still need to cover for backup/restore and restoration of image to same machine, we need to govern the behavior 1 with a config option. The default behavior should be as above, but when the config option is set otherwise, we need to allow new registration to overwrite existing agent (the current behavior). Problem as described by customer: Duplicate GUIDs cause DA/SRA previously registered to the TPC Server with the same GUID to lose connectivity to TPC Server. Initial customer impact (low/med/high): High
Local fix
None at This Time.
Problem summary
**************************************************************** * USERS AFFECTED: Users cloning server machines with GUID * * preinstalled. * **************************************************************** * PROBLEM DESCRIPTION: Since TPC indetifies the cloned * * machines with Storage Resource Agents * * uniquely based on GUID, so only one * * with last probe remains in TPC * * overwriting other, with no error given. * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
Change the registration to check if a server is already registed with same GUID and the host name is not same, Now TPC will not register the new one and give error. The fix for this APAR is targeted for the following maintenance packages: | fix pack | 4.1.1-TIV-TPC-FP0007 - target to be determined | fix pack | 4.2.1-TIV-TPC-FP0004 - target August 2011 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC76189
Reported component name
TPC FOR DATA
Reported component ID
5608TC300
Reported release
41A
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-05-06
Closed date
2011-06-10
Last modified date
2011-06-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR DATA
Fixed component ID
5608TC300
Applicable component levels
R41A PSY
UP
R41H PSY
UP
R41L PSY
UP
R41S PSY
UP
R41W PSY
UP
R42A PSY
UP
R42H PSY
UP
R42L PSY
UP
R42S PSY
UP
R42W PSY
UP