System Automation for z/OS SMF Record layout

Technote (troubleshooting)


Problem(Abstract)

A CICS Automation command processor creates SMF records that contains
subsystem names, job names, application identifiers, event types, and
event data. These records can be used for availability reporting.
The SMF layout is not described.

Cause

.

Resolving the problem

The SMF record number used is 215. If you don't want record number 215 used,

then use the SMFID keyword to specify a different record number.

CICS Automation SMF Record Layout

NAME DIS LENGTH DESCRIPTION
____ ___ ______ _____________________________


SMFRLEN 000 002 AL2(NNN) TOTAL RECORD LENGTH
SMFSEGD 002 002 X'0000'
SMFHFLAG 004 001 X'80'
X'8E' FOR MVS/ESA
SMFRTYPE 005 001 SMF RECORD TYPE FROM SMFID(X'XY')
SMFTIME 006 004 TIME SINCE MIDNIGHT (HUNDREDS OF
SECONDS)
SMFDATE 010 004 DATE IN FORMAT X'0CYYDDDF' OR
X'00YYDDDF'
SMFCASID 014 004 SYSTEM IDENTIFIER FROM SMCASID
SMFSSID 018 004 C'CAO '
* 022 END OF STANDARD SMF HEADER


SMFRVER 022 002 X'0001' (RECORD VERSION)
SMFDOMID 024 008 DOMAIN IDENTIFIER FROM MVTCURAN
SMFSUBSN 032 008 SUBSYS PADDED WITH BLANKS
SMFPROCN 040 008 PROCNM PADDED WITH BLANKS
SMFSAPPL 048 008 SPAPPL PADDED WITH BLANKS
SMFGAPPL 056 008 GNAPPL PADDED WITH BLANKS
SMFETYPE 064 001 EVENT TYPE FROM EVTYPE
X'01' CICS START-UP TIME (START)
X'02' CICS SERVICE START-UP TIME (UP)
X'03' CICS SERVICE END TIME (STOP)
X'04' CICS END TIME (DOWN)
X'05' CICS SERVICE IN PROBLEMS (HALTED)
X'06' CICS SERVICE OUT OF PROBLEMS
(UNHALTED)
065 007 XL7'00' (RESERVED)
SMFEDATA 072 XXX EVDATA (0-100 BYTES)
* 072 MINIMUM SMF RECORD LENGTH
* 172 MAXIMUM SMF RECORD LENGTH