A fix is available
APAR status
Closed as program error.
Error description
After upgrading to FP2 the customer sees an event message: Connection timed out to (xxxx:xxxx:...:xxxx): Either the host IP address is not up or there are network connectivity problems. Type: Switch
Local fix
Problem summary
The switch connection code contained an incorrect timeout value.
Problem conclusion
The connection timeout has been corrected.