APAR status
Closed as Permanent restriction.
Error description
STCAI : cgr created not consistent with data in the vault . Smarteam CATIA integration problem reproduced on SmDemo . Scenario : 1. Start CATIA. Connect to Smarteam as 'joe'. 2. Open the provided CATProduct 'Viewer.CATProduct'. 3. Save and Check in 'Viewer.CATProduct' in Smarteam. 4. Open the checked in part 'Rectangle.CATPart'. Release it. 5. Open for edit 'Viewer.CATProduct' 6. Do a modification of the released part 'Rectangle.CATPart'. Say 'no' to the COOF message. (part is dirty) 7. Check in the CATProduct 'Viewer'. (say Ok to the message about the dirty part) Problem : The cgr created for the CATProduct 'Viewer' shows the modification in the 'Rectangle' part. (this can be checked by opening the cgr in CATIA or by using the Smarteam viewer) It's not consistent with the CATProduct in the vault .
Local fix
Problem summary
STCAI : cgr created not consistent with data in the vault STCAI : cgr created not consistent with data in the vault . Smarteam CATIA integration problem reproduced on SmDemo . Scenario : 1. Start CATIA. Connect to Smarteam as 'joe'. 2. Open the provided CATProduct 'Viewer.CATProduct'. 3. Save and Check in 'Viewer.CATProduct' in Smarteam. 4. Open the checked in part 'Rectangle.CATPart'. Release it. 5. Open for edit 'Viewer.CATProduct' 6. Do a modification of the released part 'Rectangle.CATPart'. Say 'no' to the COOF message. (part is dirty) 7. Check in the CATProduct 'Viewer'. (say Ok to the message about the dirty part) Problem : The cgr created for the CATProduct 'Viewer' shows the modification in the 'Rectangle' part. (this can be checked by opening the cgr in CATIA or by using the Smarteam viewer) It's not consistent with the CATProduct in the vault .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Incident Diagnosis Product cgr file created is not consistent with data in the vault Restriction Explanation In the scenario, one Part is modified-ReadOnly. We can't unload it and can't save it. The cgr file is generated from the CATIA product in session. Therefore it contains the part modification. When doing the smarteam/save on the product, the user gets a warning message telling him that a Part is modified in ReadOnly status. Through the message, we recommend to solve this problem before saving the assembly. This is the correct way to proceed. By-Pass 1. Cancel the save 2. Solve the Modified ReadOnly problem (or CheckOut/New Release on the part) 3. Save again the assembly .
Temporary fix
Comments
APAR Information
APAR number
HD68347
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
517
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-10-17
Closed date
2007-11-24
Last modified date
2007-11-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
24 November 2007