IBM Support

HD68347: STCAI : CGR CREATED NOT CONSISTENT WITH DATA IN THE VAULT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • STCAI : cgr created not consistent with data in the
    vault
    .
    Smarteam CATIA integration problem reproduced
    on SmDemo
    .
    Scenario :
    1. Start CATIA. Connect to Smarteam as 'joe'.
    2. Open the provided
    CATProduct 'Viewer.CATProduct'.
    3. Save and Check in 'Viewer.CATProduct' in
    Smarteam.
    4. Open the checked in part 'Rectangle.CATPart'.
    Release it.
    5. Open for edit 'Viewer.CATProduct'
    6. Do a modification of the released
    part 'Rectangle.CATPart'. Say 'no' to the COOF
    message. (part is dirty)
    7. Check in the CATProduct 'Viewer'. (say Ok to
    the message about the dirty part)
    Problem : The cgr created for the
    CATProduct 'Viewer' shows the modification in
    the 'Rectangle' part. (this can be checked by
    opening the cgr in CATIA or by using the
    Smarteam viewer)
    It's not consistent with the CATProduct in the vault
    .
    

Local fix

Problem summary

  • STCAI : cgr created not consistent with data in the vault
    STCAI : cgr created not consistent with data in the
    vault
    .
    Smarteam CATIA integration problem reproduced
    on SmDemo
    .
    Scenario :
    1. Start CATIA. Connect to Smarteam as 'joe'.
    2. Open the provided
    CATProduct 'Viewer.CATProduct'.
    3. Save and Check in 'Viewer.CATProduct' in
    Smarteam.
    4. Open the checked in part 'Rectangle.CATPart'.
    Release it.
    5. Open for edit 'Viewer.CATProduct'
    6. Do a modification of the released
    part 'Rectangle.CATPart'. Say 'no' to the COOF
    message. (part is dirty)
    7. Check in the CATProduct 'Viewer'. (say Ok to
    the message about the dirty part)
    Problem : The cgr created for the
    CATProduct 'Viewer' shows the modification in
    the 'Rectangle' part. (this can be checked by
    opening the cgr in CATIA or by using the
    Smarteam viewer)
    It's not consistent with the CATProduct in the vault
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    Incident Diagnosis
    Product cgr file created is not consistent with data
    in the vault
    Restriction Explanation
    In the scenario, one Part is modified-ReadOnly. We
    can't unload it and can't save it. The cgr file is
    generated from the CATIA product in session.
    Therefore it contains the part modification.
    When doing the smarteam/save on the product, the
    user gets a warning message telling him that a Part
    is modified in ReadOnly status. Through the
    message, we recommend to solve this problem
    before saving the assembly. This is the correct way
    to proceed.
    By-Pass
    1. Cancel the save
    2. Solve the Modified ReadOnly problem (or
    CheckOut/New Release on the part)
    3. Save again the assembly
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD68347

  • Reported component name

    SMARTEAM NT>XP

  • Reported component ID

    569199970

  • Reported release

    517

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-10-17

  • Closed date

    2007-11-24

  • Last modified date

    2007-11-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
24 November 2007