A fix is available
APAR status
Closed as program error.
Error description
Using the remote debugger with Debug Tool of a COBOL V4 program with an unsigned comp-3 item which has a x'C' as the sign nibble, Debug Tool shows error message 'EQA2377E Invalid data' instead of showing the value of the data item.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users debugging Enterprise COBOL V3 or V4 * * programs with Debug Tool in remote debug * * mode. * * * **************************************************************** * PROBLEM DESCRIPTION: Using Debug Tool remote debug of a * * COBOL program with an unsigned * * COMP-3 item such as: * * * * PDC-UNSIGN USAGE COMP-3 PIC 9(08) * * * * and there is a x'C' as the sign * * nibble, Debug Tool shows error message * * 'EQA2377E Invalid data' instead of * * showing the value of the data item. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** The COBOL runtime did not consider a sign nibble value of x'C' as a valid value for an unsigned COMP-3 data item.
Problem conclusion
The COBOL runtime will be changed to support all valid sign nibbles for an unsigned COMP-3 data item: x'A', x'C', x'E', x'F' when running under Debug Tool.
Temporary fix
Comments
APAR Information
APAR number
PI77390
Reported component name
LE COBOL LIB
Reported component ID
568819802
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-02-28
Closed date
2017-03-08
Last modified date
2017-04-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI45429 UI45431
Modules/Macros
IGZIC41
Fix information
Fixed component name
LE COBOL LIB
Fixed component ID
568819802
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB16","label":"Mainframe HW"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M","label":"APARs - z\/VM environment"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790"}]
Document Information
Modified date: