OA30556: MSGIRRU080I STRANGE ABEND CODE ???X'60560000'X'6F6FFFFF' IN CONJUNCTION WITH VSAM IEC161I 056-084 062-086

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as fixed if next.

Error description

  • During RACF RRSF initialization, if the VSAM files had not been
    closed correctly during a previous shutdown, msg IEC161I is
    issued with both RC56 RSN84 and RC62 RSN86 as VSAM cleans up the
    files.
    This gets the RRSF ESTAE involved within IRRSSQ10 (HANDLE_ABEND)
    to issue msg IRRU080I.   But because there is no SDWA, several
    fields are left uninit'd:
     IRRU080I (<) RACF RACF VSAM FILE OPEN AND CLOSE PROGRAM
     ENCOUNTERED AN ERROR.  ABEND CODE IS ???X'60560000'X'6F6FFFFF'.
    
    The fields are DASH_LENGTH and DUMP_REASON_CODE_LEN.
    This causes the RACF msg routine to use a default length of 4
    for each field, which is incorrect.
    The msg should end with:   ABEND CODE IS ???.
    
    
    Additional Symptoms:
      msgIEC161  IEC161  RC056 RC062 RSN084 RSN086
      msgIRRU080 IRRU080
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: User's  who experience  problems while  RRSF *
    *                 (RACF  Remote  Sharing  Facility)  opens  in *
    *                 message  or  out  message   data  sets,  who *
    *                 receive   either  of   the  error   messages *
    *                 IRRU080I  or IRRU081I,  which indicate  that *
    *                 RACF experienced an abend, but  do not see a *
    *                 dump taken.  The  messages indicate an abend *
    *                 code which begins  as ???  and  then becomes *
    *                 garbled.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    IRRU080I or IRRU081I messages may  be incorrectly issued when no
    abend has  in fact  occurred.   In these  instances no  SDWA was
    provided.    An  abend  code  of ???-??    is  attempted  to  be
    displayed.  However the message ends garbled.
    

Problem conclusion

Temporary fix

Comments

  • This Apar is being closed FIN with concurrence from
    the submitting customer.  This means that a fix to
    this Apar is expected to be delivered from IBM in a
    release (if any) to be available within the next
    24 months.
    

APAR Information

  • APAR number

    OA30556

  • Reported component name

    RACF

  • Reported component ID

    5752XXH00

  • Reported release

    760

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-09-25

  • Closed date

    2010-02-09

  • Last modified date

    2010-02-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R760 PSN

       UP



Document information


More support for:

z/OS family

Software version:

760

Operating system(s):

MVS, z/OS

Reference #:

OA30556

Modified date:

2010-02-09

Translate my page