IZ99749: CL_EXTENDVG INCORRECTLY ASSIGNS PVIDS ON BOTH HDISKS AND VPATH

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Adding a volume to a volume group via C-SPOC menu results
    in assigning PVIDs to both the hdisks and vpaths. There
    is also a syntax error in the invocation of cl_dpovgfix
    by cl_extendvg script.
    

Local fix

Problem summary

  • Adding a volume to a volume group via C-SPOC menu results
    in assigning PVIDs to both the hdisks and vpaths. There
    is also a syntax error in the invocation of cl_dpovgfix
    by cl_extendvg script.
    

Problem conclusion

  • 1. Using cl_lsfreedisks to provide a select list of potential
    disks for extending VG. Wad cl_lspvids but could not keep
    VG either all hdisks or all vpaths.
    2. clgetpvid rejected all vpath device. It was corrected in
    defect 777918
    

Temporary fix

Comments

APAR Information

  • APAR number

    IZ99749

  • Reported component name

    HACMP VER 5

  • Reported component ID

    5765F6200

  • Reported release

    550

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2011-05-02

  • Closed date

    2011-05-02

  • Last modified date

    2011-09-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    U846803

Fix information

  • Fixed component name

    HACMP VER 5

  • Fixed component ID

    5765F6200

Applicable component levels

  • R550 PSY U846803

       UP11/09/13 I 1000



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

PowerHA

Software version:

550

Operating system(s):

AIX

Reference #:

IZ99749

Modified date:

2011-09-13

Translate my page

Machine Translation

Content navigation