A fix is available
APAR status
Closed as program error.
Error description
For PowerHA customers at AIX levels 7.1.5 or 7.2.2 (RSCT 3.2.3.0), if there is a service IP alias on the same subnet as the boot address, and the adapter is declare down, while IP changes are being made to move the service address somewhere else, PowerHA will receive a report that the adapter is back up again, even if it is still down. The resulting false network_up event will not break the failover itself, but it will introduce a danger of future resource movements being handled inappropriately, if they occur while the adapter is still down and PowerHA is still being told it is up.
Local fix
Problem summary
At RSCT 3.2.3.0, a logic error in handling AHAFS events during PowerHA IP address handling, when a service and boot address are on the same subnet, could lead to Group Services erroneously reporting that an interface is UP again when it is still down.
Problem conclusion
The error in handling this specific sequence of events has been addressed.
Temporary fix
n/a
Comments
APAR Information
APAR number
IJ06703
Reported component name
RSCT FOR AIX
Reported component ID
5765F07AP
Reported release
323
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2018-05-26
Closed date
2018-07-02
Last modified date
2021-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RSCT FOR AIX
Fixed component ID
5765F07AP
Applicable component levels
R323 PSY U889770
UP21/09/02 I 1000
PTF to Fileset Mapping
U881668 rsct.basic.rte 3.2.3.2
U883597 rsct.basic.rte 3.2.3.3
U887098 rsct.basic.rte 3.2.3.5
U885259 rsct.basic.rte 3.2.3.4
U883597 rsct.basic.rte 3.2.3.3
U881668 rsct.basic.rte 3.2.3.2
U881668 rsct.basic.rte 3.2.3.2
U883597 rsct.basic.rte 3.2.3.3
U885259 rsct.basic.rte 3.2.3.4
U885259 rsct.basic.rte 3.2.3.4
U887098 rsct.basic.rte 3.2.3.5
U887098 rsct.basic.rte 3.2.3.5
U889770 rsct.basic.rte 3.2.3.6
U889770 rsct.basic.rte 3.2.3.6
U889770 rsct.basic.rte 3.2.3.6
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11O"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"323"}]