  • INTRAN

Error description

  • This APAR continues II10001, 11013, 11513, 12140, 12615, &
    II13278, in documenting symptoms/bugs related to VSAM, Catalog,
    IDCAMS & RLS caused by various OEM vendor products or other IBM
    products.
    KEYWORDS:  VSAMBUGS INFOAPAR and INFOAPAR5.
    --------------------------------------------------------------
    

Local fix

  • 273)  IDCAMS DEFINE PAGESPACE returns ABEND0D3 RC13  ILR028I
          ( MSGILR028I ). Due to a VSAM Optinization Product from
          Serena Software Called : IOO.  (only seen in R1G0). The
          workround is a DD Statement :  //UTL@SOFF  DD  DUMMY
          Fix will be inb next release   NEWREQ # : 18408
    274)  USing BMC STOPx37 product receive messages:
    
           MSIGEC070I 104-204,jobname,stepname,ddname
           MSGIEC070I dsname
    
           MSGSMS4000I jobname,stepname,ddname,ATTEMPTING SPACSECR
             or SPACVOLA dsname
           MSGSMS4400I VOLUME ADDED - OLD VOLUME volser, NEW VOLUME
           SMS
           MSGIEC614I EXTSAME FAILED - RC 008, DIAGNOSTIC INFO
           (08250419)
           BMC fix for STOPx37 BPG2551.  5/27/03
     275) Abend 378 occurs when VSAM file is trying to EXTEND
          Running Mobius ViewDirect INFOPAC
          Abend378 SVC 78 IDA0557A + 16B2 IDA0192A + 02FB42
          BMC fix BPG2392
    #276) Via batch job IDCAMS issues ALTER GDG LIMIT(255)
          In the JES2 msglog ( joblog ) user receives a message
          with no message number that is undocumented:
          "MORE THEN 50 DATASET NAMES ARE BEING UNCATALOGED"
          The message issuer is Computer Associates product CA-1.
          CA-1 PTF QO31009 fixes the problem with the message.
          6/30/03.
    #277) MSGIEC070I 209-220 for a KSDS that spans volumes.
          Using Computer Associates CA product CADISK.
          Computer Associates fix number is T25B040. 7/1/03.
    278)  ABEND0F4 RC24 RSN66840327 due to DEFRAG of volume
          while data set was open. Improperly moved data
          set is later detected by SMSVSAM.
          FDR COMPAKTOR ZAP P-54.2412 changes the GQSCAN
          that is issued for Qname SYSVSAM to an ENQ with
          RET=TEST.
    #279) VSAM Media Manager ICYABN issues logrec entries for
          i/o errors "Record Not Found". Using BMC Recovery Plus
          product. BMC fix number P390894. 7/15/03.
    #280) ABEND0C6 ABEND 0C6 , IDA0557F
          BMC module PRS43410 hooking into VSAM EOV
          At offset X'1E4' they are trying to go to IDA0557G. Inst
          98ECD00C 58F0CA88 07FF. Reg 12 is their base reg.
          R12+A88 is the pointer to IDA0557G. LM restores R12
          to IDA0557F base register & at IDA0557F+A88 is the string
          E3E8D7C5.
          BMC APAR #BAG1624
          VSAM EOV HOOK NOT ALWAYS CALLING IDA0557G UNDER Z/OS 1.3
          AND HIGHER IN SYSTEMS WITH STOPX37/II ACTIVE.
    #281)
    Resolution ID: 128721
    Type: SYSMOD - APAR
    BAG1629 SYSTEM 0C4 ABEND OCCURED AT OFFSET X'????' IN MODULE PRS
    VSAM EOV NON-SMS
    non-sms vsam eov datasets got abend 0c4 when SVOS goes to
    IDA0557B USING 31 BIT UCB'S AND zOS 1.3.
    IOS071 and IOS431 messages affecting system.
    Many abends in CAS leading to severe contention and
    possible hang in catalog.
    #282)  ABEND0C1 during DEFINE ALIAS.  The abend is in non code
           area.  Reg-12 in the dump is a base register for ACF2
           module ACF95LA1.
           The response from ACF2 is a problem is in ACF95LA1
           after apar QO40981.  The fix is to apply QO41452.
           08/06/03
    #283) SVC1 WAIT in loadmod IDA019L1 csect IDA019SE at or near
          offset x'3AC' depending on PTF level. OEM program from
          Systemware Software has issued a WRTBFR with TYPE=DS
          without first quiescing all i/o to the ds. This is a
          documented requirement per the Macro Instructions for
          Data Sets manual under WRTBFR. Systemware fix =
          SWJJ229. 8/25/03.
    #284) BIMSDLI application abend0c4 in IDA0557A, sometimes
          preceded by msgiec070i 203-204 with reg8 pointing to
          ACCHOOK module from DTS.
          DTS SRS FIX DETAILS:
    DTS31348
    STATUS: Included in ACC 3.1.12 and  4.1 source
    SYMPTOM: ABENDS0C4 in IDA0557A after SRS ADDVOL on a VSAM datase
    with imbedded index.
    This fix is included in the latest version of DIF ( 3.1.12 ) and
    SRS ( 3.1.11 ) - both of which are available for download from
    the DTS website http://www.dtssoftware.com
          08/25/03
    #285) ABEND0C4 in IDA0557A extending a KSDS with IMBED.
          Register 8 points the the BMC hook LODRSTUB IDA0557B.
          BMC fix is: RESOLVE SRM 5.1  - BPG2759
    MAINVIEW SRM 6.1 - BPG2551
    MAINVIEW SRM 7.1 - BPG2580
          09/03/03
    #286) symptoms: BMC MAINVIEW SRM 6.1
    customer migrating from OS390 2.10 to z/OS 1.3 Experienced loop
    in EOV/extend processing ( extended KSDS dataset with dataclass
    volume count 7 and additional volume amt=secondary.
    FIX: Contact BMC for APAR BAG2038 / PTF BPG2988 / expected
    availability after Sept 22, 2003. (DWH, 09/03/2003)
    #287) ABEND0C4 in IGG0CLA0 on OEM vsam/catalog call from
          module PRS40020. Messages may include OEM message
          MSGSMS9035I SMS9035I. OEM product PROSTART needs a
          DD DUMMY card in the JCL PROC: //PROIGN  DD  DUMMY.
          9/15/03.
    #288) This entry is in addition to item #114 from info
          APAR II11513. That apar describes problems with
          the Mobius INFOPAC product and its INVERS1 and
          INDIST ( INVERS INDIST ) VSAM files. It recomends
          that INFOPAC OPTION28 be set to YES in order that
          a VERIFY REFRESH be done every time INFOPAC opens
          these shroption 4,3 files for OUTPUT. However, it
          has been found that the REFRESH is not always done
          even when OPTION28=YES. MOBIUS has produced a PTF
          named FRVERIFYALL that must also be applied for the
          REFRESH to be done every time. Symptoms may include
          broken VSAM ds's with IDCAMS EXAMINE error messages
          IDC11772I HORIZONTAL POINTER CHAIN LOOP or
          IDC11705I INDEX RECORD CONTAINS DUPLICATE INDEX POINTERS
          MSGIDC11772I MSGIDC11705I
          09/30/03. saw
    #289) ABEND0C4 in CICS module DFHFCVR at offset X'FFFF'.
          Further diagnosis revealed ABEND0C4 in LMOD IDA019L1
          at X'0107F8' CSECT IDA019RU at X'13E8'. The AMB
          indicates a GSR request and the RPL indicates an
          ASYNCHRONOUS PUT request. TRANISO (Transaction Isolation)
          is specified in CICS. There is a restriction using
          TRANISO with GSR. When using TRANISO all VSAM files must
          be under LSR. Either use LSR or turn off TRANISO. See
          OW16189 and II09208.
    #290) Using EMC snap program EMCSNAP ( A.K.A
          SIBBATCH ) receive msgiec614i with DADSM
          diagnostic information 04034336. ( x'4336' =
          decimal 17206, SMS rsn code meaning not enough
          volumes with sufficient space to extend the ds ).
          Two ZAPS to OEM SCFGBLCD module are available from
          the EMC Corp. SF53061 fix number. 10/21/03
    #291) Using SMB, BLSR invoked automatically anddefault
          of STRNO 16 causes 6K of SQA to be used. CA
          Easytrieve incorrected setting up ACB w/o specifying
          RMODE31=ALL. Product: CA-EZTPLS Ezytrieve Release:
          R6.4 Fix: Q042486 Module: EZTPA04 10/28/03
    #292) ABEND0c4 pic11 in ICYMMSRV according to LOGDATA, however,
          ABEND0c4 pic11 actually occuring in CSECT TS$CLS32 of
          loadmodule SWTS320 at offset +00F6 on a TM instruction
          that uses reg1 ( r1 ) which points to storage that is not
          available.  This occurred after applying RSU0303 - RSU0308
          maintenance.  The ABEND0c4 is followed by many ABEND378
          ( abend0378 s0378 abendS378 ) reason code 14 ( rsn14
          reason=00000014 ) in IXGA1MM.
          Problem in Terasam ZAP TSM32311 and is fixed by TSM32340.
    #293) User Abend 0009 PSW = 80BBB7DE located in CA module
          beginning at 00BBB2F0. Followed by DB2 abend 04E.
          Media Manager return code = 00301114( rc=00301114 )
          from functional recovery module ICYFRR.
          CA suggests PTF QO35461 for Service Pack 2, PTF
          QO37483 for the ABENDU0300, PTF QO43679 (Problem 79)
          introduced an error that may cause S0C4 abends in ASXIOHK,
          and PTF QO32130.
    294) SMSVSAM abend0f4 rsn611BFB3D due to EMC TimeFinder
    product incorrectly updates the AMDNEXT field in the Catalog.
    EMC TimeFinder 5.2  fix SF520B7 10/15/2003
    #295) Receiving error msg IDC3003I RC12 on DELETE with no
    accompanying msg. Getting IDC3009I rc8cc42 on LISTCAT.
    Also found abend0c4 pic11 is occurring in Catalog module
    IGG0CLXE (BASE/HDZ11G0) + x'72' on a TM instruction at offset
    x'6A'. IAMSVC32 issues CPL, have a SVC 26 front end replacement
    installed for all SVC 26 requests. Passes wrong ptr in CPL.
    IAM Innovation fix number P80.0083. 12/12/03
    .
    #296 IEC070I 203-220 on an Extended Striped Vsam data
         set Problem was introduced from maintenance for
         BMC (a SPACVOLA attempt) by Stopx37. Limited to
         extended striped vsam data sets. BMC has a ZAP
         till fix BPG3197 is avail on 1/21/04.
    #297) MSGIEC999I IGGPRE00,CTS7094
          MSGIEC070I 211(16,300)-221,
          ABEND0C4 in DADSM pre-exit IGGPRE00
          MSGIDC3351I ** VSAM I/O RETURN CODE IS 28
            RPLFDBWD = X'2908001C'
          PRODUCT: CA-Allocate   RELEASE: 5.3
          PTF #:   QO48394       DATE:    16 DEC 2003
          1/8/2004
    #298 IEC070I 209-220 - Fix for CA-Allocate
    required for z/OS. PTF number is QO46456.
          1/9/2004
    #299) Not an OEM bug, but a pointer to a DB2 fix for
          a VSAM DS related problem.
          SYMPTOMS: Receive MSGIEC070I 220-202 after creating
          a DB2 Index DS. See DB2 apar PQ78780. 1/13/2004
          RC220 RSN202.
    #300) MSGIEC161I 120-053 RC120 RSN53 installing OEM Candle
          OMEGAMON II 5.2.0 for CICS after migrating to Z/os
          1.3 or above. In Z/OS 1.3 a change to the INDEX CISIZE
          algorthm results in larger INDEX CISIZES than on
          prior releases. This is described by IBM info apar
          II13288. The RC120 RSN53 occurs when the BUFFERSIZE
          specified in the OEM OMEGAMON ACB is not large enough to
          accomodate a full CI of the new larger size.
          CANDLE CORP: RESOLUTION:
    C2520 IEC 161I Reason code 120 - 053 ans it's VSAM file RKC2TDOO
    says Bufferspace inadequate
    Problem:
    A change to DFP, documented by IBM APAR  II13288, results in the
    recalculation of the VSAM INDEX CISIZE for whichever datasets ar
    affected.  The LSRPOOL definitions for the CUA address space do
    include a pool with a 10240 byte  buffer.  As a result, message
    120-053 and/or message "KLVVS001 OPEN FAILED" is received and th
    can not be started.
    
    
    Solution:
    If you have PTF QCI4581 applied, then you must select OMEGAMON I
    CICS product configuration and  Recreate Runtime Members for eac
    the RTEs that the product is installed in.
    
    If you do not have PTF QCI4581 applied please follow these steps
    circumvent the problem:
    1.  ShutdownOmegamon II for CICS  address space
    2.  Copy &rhilev.RKANPAR(KC2SYS00) to &rhilev.RKANPAR(KC2SYS0X)
    3.  Edit &rhilev.RKANPAR(KC2SYS00)
    4.  Replicate line LSRPOOL(2048,8) and change 2048 to 16384, so
    looks like: LSRPOOL(16384,8)
    You must restart the Omegamon II For CICS  CUA address space for
    above changes to take affect.
    01/22/04.
     #301) Receive the message IEC161I 052(13)-84 when attempting
           to open an AIX file to CICS. GRS display for SYSVSAM
           shows the path and the base cluster allocated to CICS,
           but CICS does not see the file open. The inhibit update
           bit is off. IDA0192B is at UA01130. Fix is CA-ALLOCATE.
           PTF is QO46521.   01/28/04
    #302) Automon/RDO for Os/390 by Unicom Systems in BETA test
          version set the default DEFINE CLUSTER of its COMMAND
          STORAGE file. It set the default to (3,4). The 4 is the
          "Cross-system" shareoption. After defining the file as
          (3,4) it no longer extends, receiving CICS errors:
           AP 04E1 FCFR EXIT - FUNCTION(WRITE) RESPONSE(EXCEPTION)
    REASON(INSUFFICIENT_SPACE) ACCMETH_RETURN_CODE(00000000)
           Per the Access Method Services manual description of
           cross-system shareoption 4:
    "Output processing is limited to update or add processing that
     does not change either the high-used relative byte address
     (RBA) or the RBA of the high key data control interval if
     DISP=SHR is specified."
           SOLUTION: The OEM vendor has changed the default
           SHAREOPTION to (3,3). 2/13/04.
    303 - Receive msgIEC161i 064(0000000C 000C0004)-0341 opening
          a VSAM data set under RLS (would receive different sfi
          data opening under regular VSAM), after VSAM data set
          was REPROd using EMC's VSAM Assist.  Fix number is
          VAS67345 and needs to be applied to both VSAM Assist and
          to EMC's (Performance Essentials) VSAM IO (VIO) product.
          ref pmr 45381,033 - 18 Nov 2004
    

Problem summary

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    II13603

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    INTRAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-05-27

  • Closed date

  • Last modified date

    2004-11-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels



Document information


More support for:

z/OS family

Software version:

001

Operating system(s):

MVS, OS/390, z/OS

Reference #:

II13603

Modified date:

2004-11-18

Translate my page

Content navigation