A fix is available
APAR status
Closed as program error.
Error description
DETAILS OF PROBLEM: TPC Performance Monitor job fails to retrieve Statistic files as "not found" when TPC requests them. This may occur for a new SVC Performance Monitor and also when re-enabling an existing SVC PM job. When collecting Performance Monitor statistics files using SVC CLI over SSH method (not CIMOM), retrieving statistics files may fail with a message stating the Stats files are not available. Example: When collecting data from SVC with 15 minute interval, a new set of statistics files should become available anytime within the 15 minute interval. Statistics files may become available on the config-node much earlier than the 15 minute mark. TPC will not look for the files the 15 minute mark. TPCs mechanism to determine whether the statistics files are too old may cause the current statistics to be marked as "old". As a result the set of statistics files will not be selected as they are older expected. The performance monitor job will show this error for the first and subsequent failed collection attempts in TPC logs: "HWNPM2052E: No performance data was collected from device SVC NAME for the current collection interval due to an error. The previous polling interval with data was at (null)." . Recreate Steps: Difficult to recreate this problem as it's a timing related out of sync situation.
Local fix
Problem as described by customer: TPC performance monitor jobs fail and are unable to collect statistics as expected. Initial customer impact (low/med/high): med Local Fix: n/a
Problem summary
**************************************************************** * USERS AFFECTED: TPC 4.2.x customers running SVC * * performance data collection with 15 * * minutes interval. * **************************************************************** * PROBLEM DESCRIPTION: This problem might occur with a new * * SVC Performance Monitor when * * statistics files are not available * * when TPC requests them. The * * performance monitor job will show * * this error for the first and * * subsequent failed collection attempts. * * "HWNPM2052E: No performance data was * * collected from device SVC NAME for * * the current collection interval due * * to an error. The previous polling * * interval with data was at (null)." * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
The error message "HWNPM2052E" will be seen once for the first sample but the data should be collected for the subsequent attempts. The fix for this APAR is targeted for the following maintenance packages: | fix pack | 4.2.1-TIV-TPC-FP0004 - target August 2011 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC76634
Reported component name
MDM PERFORMANCE
Reported component ID
5648GPC01
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-05-25
Closed date
2011-08-01
Last modified date
2011-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MDM PERFORMANCE
Fixed component ID
5648GPC01
Applicable component levels
R420 PSY
UP