A fix is available
APAR status
Closed as program error.
Error description
Executing /usr/lpp/diagnostics/bin/uesensor -l returns the message "There are no environmental sensors on this system." However, the system may or may not have environmental sensors. In some cases, firmware chooses not to expose the environmental sensors to the operating system. Of course, if any of the environmental sensors indicated a value out of normal operating range, then an error would get reported to the operating system and AIX diagnostics would analyze and report the error.
Local fix
Executing /usr/lpp/diagnostics/bin/uesensor -l returns the message "There are no environmental sensors on this system." However, the system may or may not have environmental sensors. In some cases, firmware chooses not to expose the environmental sensors to the operating system. Of course, if any of the environmental sensors indicated a value out of normal operating range, then an error would get reported to the operating system and AIX diagnostics would analyze and report the error.
Problem summary
Executing /usr/lpp/diagnostics/bin/uesensor -l returns the message "There are no environmental sensors on this system." However, the system may or may not have environmental sensors. In some cases, firmware chooses not to expose the environmental sensors to the operating system. Of course, if any of the environmental sensors indicated a value out of normal operating range, then an error would get reported to the operating system and AIX diagnostics would analyze and report the error.
Problem conclusion
Change /usr/lpp/diagnostics/bin/uesensor in devices.chrp.base.diag to output the message "This function is not supported on this system." whenever firmware is not exposing any environmental sensors to the operating system.
Temporary fix
Comments
APAR Information
APAR number
IY46601
Reported component name
AIX 5L POWER V5
Reported component ID
5765E6200
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2003-07-17
Closed date
2003-07-17
Last modified date
2004-04-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5L POWER V5
Fixed component ID
5765E6200
Applicable component levels
R520 PSY U488956
UP04/04/21 I 1000
PTF to Fileset Mapping
U488956 devices.chrp.base.diag 5.2.0.30