IBM Support

IC95061: VIRTUAL SYSTEM PATTERN SCRIPT PACKAGE FAILS TO COMPLETE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A virtual system pattern script package that worked in IBM
    PureApplication System v1.0 fails to complete after upgrading to
    IBM PureApplication System 1.1
    
    Last line logged in wsadmin.trace is -
    
    [7/22/13 19:53:16:462 UTC] 00000001 AbstractShell A   WASX7091I:
     Executing script:
    "/tmp/ConfigureJAASAuthAlias/configureJAASAuthAlias.py"
    
    The script package was timing out due to a timeout value that
    was too low.
    

Local fix

  • Check the script timeout setting.
    
    Timeout is the maximum amount of time, expressed in
    milliseconds, in which the script is expected to complete its
    execution.  The value of this parameter is displayed in the
    Timeout field of the Script Packages pane when the compressed
    script package is uploaded.
    
    The default value is 60000000 (1000 minutes). A value
    of 0 specifies to wait indefinitely for the script to complete.
    
    If the timeout value is exceeded, Status.TIMEOUT_FAILED is
    returned, and execution is stopped.
        Example (timeout value of 2 minutes, specified as 120,000
    milliseconds):
    
        "timeout": "120000",
    
    When the script package is downloaded, this value is written
    in the cbscript.json file.
    

Problem summary

  • The script package timeout value in milliseconds was being
    ignored in IBM PureApplication System version 1.0. The default
    value of 60000000 milliseconds was used. After the upgrade the
    the script package timeout value set in the script package is
    being used.
    

Problem conclusion

  • The code executing script packages was updated to parse and use
    the timeout value specified by the users.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC95061

  • Reported component name

    PUREAPP SYS W15

  • Reported component ID

    5725G3200

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-08-20

  • Closed date

    2013-09-03

  • Last modified date

    2013-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PUREAPP SYS W15

  • Fixed component ID

    5725G3200

Applicable component levels

  • R110 PSY

       UP

  • R100 PSN

       UP

  • RESP PSN

       UP